1. |
|
Preparation Tools
Filters Dry floor-cloth
Screw-driver
Filter-spanner
Water-bottle Tissues |
|
|
|
|
|
| |
2.
Turn off the power supply. |
|
|
|
|
| |
3.
Cut off the water supply. |
|
|
|
|
| |
4.
Drain about 2 liters of water from the purifier to relieve the pressure. |
|
|
|
|
| |
Tip.
1) Spread a dry floor-cloth under the used filters to prevent a bottom water flow.
2) Pull out the in-let hose from the used 1st sediment filter. 3) Connect this hose to in-let on new 1st sediment filter. |
|
|
|
|
| |
5.
Freshing the 1st Sediment filter. |
|
|
|
|
| |
6.
Freshing the 2nd Pre-Carbon filter.
During the freshing, it is absolutely normal that a black water comes out for a while.
This is an emission of carbon-dust.
Drain about 2 liters of water. |
|
|
|
|
| |
7.
Freshing the 3rd Membrane filter for about 3 or 4 minutes. |
|
|
|
|
| |
8.
Freshing the 4th Post-Carbon filter.
During the freshing, it is absolutely normal that a black water comes out for a while.
This is an emission of carbon-dust.
Drain about 2 liters of water |
|
|
|
|
| |
9.
Unscrew the front-case. |
|
|
|
|
|
|
| |
11.
Spread a dry floor-cloth under the used filters to prevent a bottom water flow. |
|
|
|
|
| |
12.
Pull out the fitting on Water In-let & out-let with filter-spanner.
Then replace the filters one by one. |
|
|
|
|
| |
13.
Open the water supply. |
|
|
|
|
| |
14.
Check a water leakage with tissues. |
|
|
|
|
| |
15.
Close the front-case. |
|
|
|
|
| |
16.
Screw the front-case. |
|
|
|
|
| |
17.
Check it if water comes out or not. |
|
|
|
|
| |
18.
Turn on the power supply. |
|
|
|
|
|